How do I get the front cover off a Vokera Linea 24 boiler?
Boiler has completely died. No sign of life whatsoever - not even any lights. 3amp fuse OK and power to socket but have been told there is a glass fuse inside which has probably blown. Trouble is I can't work out how to remove the front cover to gain access. Not normally this thick! Any suggestions?
2 brass screws @ top of control panel onder drop-down panel.
Posssible faults.
1)Neutral wire has become detached/broken.
2)2A fuse on PCB (next to M16) has blown.
3)Mode selector switch has (physically) broken, so not actually influencing the main potentiometer on the display PCB. (Quite common, but easily overlooked!)
Gas Appliances should only be Serviced by competent, qualified, Gas Engineers, Registered with CORGI, who are more likely to recognise and safely rectify a malfunction, in accordance with The Gas Safety Regulations.
Information posted by users should be considered for general guidance only. Users act, or refrain from action, on the basis of such information entirely at their own risk.